A Compilation of Selected Air Pollution Emission Control Regulations and OrdinancesUnited States Department of Health, Education, and Welfare, Public Health Service, Division of Air Pollution, 1965 - 123 sider |
Inni boken
Resultat 1-5 av 27
Side 5
... less on an ash free and moisture free basis . ( 23 ) Mist . A suspension of any finely - divided liquid in any gas or atmosphere . ( 24 ) Multiple - Chamber Incinerator . Any article , machine , equipment , contrivance , structure or ...
... less on an ash free and moisture free basis . ( 23 ) Mist . A suspension of any finely - divided liquid in any gas or atmosphere . ( 24 ) Multiple - Chamber Incinerator . Any article , machine , equipment , contrivance , structure or ...
Side 17
... less than No. 3 on said Chart , or of an opacity which obscures vision to a degree equal to or greater than smoke of No. 2 density on the Standard Smoke Chart , but less than No. 3 on said Chart , if such emission continues for longer ...
... less than No. 3 on said Chart , or of an opacity which obscures vision to a degree equal to or greater than smoke of No. 2 density on the Standard Smoke Chart , but less than No. 3 on said Chart , if such emission continues for longer ...
Side 21
... less than 10 microns in size , if any , up to a maximum increase of 0.03 ( H / 100 ) grains per scf , where H is the height of discharge in feet above grade . ( 2 ) The limitation on the emission of that portion of the particulate ...
... less than 10 microns in size , if any , up to a maximum increase of 0.03 ( H / 100 ) grains per scf , where H is the height of discharge in feet above grade . ( 2 ) The limitation on the emission of that portion of the particulate ...
Side 24
... less stringent than the design emission limitation and recognizes that field operating conditions do not always meet design conditions and that this could cause a temporary degradation in over - all equipment performance . The more ...
... less stringent than the design emission limitation and recognizes that field operating conditions do not always meet design conditions and that this could cause a temporary degradation in over - all equipment performance . The more ...
Side 27
... less . If the capacity rating of the fuel burning equipment is more than 10 million , the amount of particulate matter which may be emitted for each million Btu input shall decrease as the capacity rating of the fuel burning equipment ...
... less . If the capacity rating of the fuel burning equipment is more than 10 million , the amount of particulate matter which may be emitted for each million Btu input shall decrease as the capacity rating of the fuel burning equipment ...
Andre utgaver - Vis alle
A Compilation of Selected Air Pollution Emission Control Regulations and ... Robert A. Taft Sanitary Engineering Center Uten tilgangsbegrensning - 1965 |
Vanlige uttrykk og setninger
AIR POLLUTION CONTROL ALLEGHENY COUNTY allow the emission allowable emission atmosphere basic emission Berkeley Berkeley Berkeley Bessemer converters blast furnaces CALIFORN CALIFORNIA LIBRARY capacity rating coarse solid particles combustion concentration containing Correction Pounds County darker than Shade density devices discharge effect factor Emission Control emission in pounds emission limitations emission of particulate emitted exceed exhaust gas fluoride fly ash fuel burning equipment gaseous gases gasoline Height of Emission Hour per Acre hydrocarbon incinerator intermediate values Interpolate for intermediate Lb/Hr Listed under Regulations materials open hearth furnaces Particulate Emissions particulate matter permit person shall cause Pertaining to Particulate POLLUTION CONTROL CODE POLLUTION CONTROL DISTRICT pounds per hour Process Weight Rate prohibited provisions of Section rate of emission Regulations Pertaining Ringelmann Chart smoke units solid fuel source of emission source operation stack height stack or chimney sulfur dioxide tank tank truck UNIVERSITY OF CALIFORNIA weight per hour Zoning Ordinance
Populære avsnitt
Side 4 - Air pollution" means the presence in the outdoor atmosphere of one or more air contaminants in...
Side 13 - A person shall not discharge into the atmosphere from any single source of emission whatsoever any air contaminant for a period or periods aggregating more than three minutes in any one hour which is : (a) As dark or darker in shade as that designated as No. 2 on the Ringelmann Chart, as published by the United States Bureau of Mines, or (b) Of such opacity as to obscure an observer's view to a degree equal to or greater than does smoke described in subsection (a) of this Rule.
Side 73 - RULE 62.1 (Adopted 1-14-64) (a) A person shall not burn within the Los Angeles Basin at any time between the days of November 16 of any year and April 14 of the next succeeding calendar year, both dates inclusive, any fuel described in the first paragraph of Rule 62 of these Rules and Regulations.
Side 6 - process weight per hour" means — (A) in the case of continuous or long-term operation, the total process weight for the entire period of operation or for a typical portion thereof, divided by the number of hours of such period or portion thereof...
Side 21 - ... matter except in conformity with the limits set forth as follows: (1) The basic limitation on the average emission into the atmosphere of particulate matter from any single such source of emission shall be 0.35 grains per cubic foot of gas measured at a temperature of 60 degrees Fahrenheit and a pressure of 30 inches of mercury, under steady conditions, provided that for emissions at levels 100 feet or more above grade, the basic limitation shall be increased by the amount of particulate matter...
Side 107 - DENSITY per hour per stack is prohibited, including smoke of a density in excess of Ringelmann No. 2- However, once during any three-hour period each stack may emit up to 62 smoke units - not to exceed Ringelmann No.
Side 7 - Unit operation: Methods where raw materials undergo physical change; methods by which raw materials may be altered into different states, such as vapor, liquid, or solid without changing into a new substance with different properties and composition.
Side 82 - ... roof. resting on the surface of the liquid contents and equipped with a closure seal, or seals, to close the space between the roof edge and tank wall. The control equipment...
Side 116 - Add together the individual rates of emission derived above of each source to obtain the total net rate of emission from all sources within the boundaries of the lot. Dust and other types of air pollution, borne by the wind from such sources as storage areas, yards, roads and the like within lot boundaries, shall be kept to a minimum by appropriate landscaping, paving, oiling, fencing or other acceptable means. Emission of particulate matter from such sources in excess of the weight limitations specified...
Side 96 - F, and when the fuel tank is between one-fourth and one-half full, averaging three-eighths full. The standard was developed from data obtained when fuels averaging a Reid Vapor Pressure of approximately 9 were used, and when hydrocarbon emissions were collected in condensing traps at dry ice temperature. Equivalent methods and other conditions may be used if approved by the Dept.