" The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tables. "
Standard American Cyclopedia of Steam Engineering: A Treatise on the Care ... - Side 43
av Calvin Franklin Swingle - 1913 - 1249 sider
Uten tilgangsbegrensning - Om denne boken

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 708 sider
...i,6oo,oco 890 'i43° 1,700,000 930 I<49° 1,800,000 970 i 550 1.900,000 1,010 1,610 3,000,000 ',050 '1670 The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the >iigh insulations by the heat of the wires, but not from fear of igniting the insulation. The question...
Uten tilgangsbegrensning - Om denne boken

Transactions of the American Society of Mechanical Engineers, Volum 19

American Society of Mechanical Engineers - 1898 - 1122 sider
...1,600,000 890 1,430 1,700,000 980 1.490 1.800.000 970 1,550 1,900.1100 1,010 1 610 2.000.000 1,050 1 670 The lower limit is specified for rubber-covered...not taken into consideration in the above tables. The carrying capacity of sixteen and eighteen wire is given, but no smaller than fourteen is to be...
Uten tilgangsbegrensning - Om denne boken

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 sider
...conductivity, according to the standard adopted by the American Institute of Electrical Engineers. The lower limit is specified for rubber-covered wires...not taken into consideration in the above tables. The carrying capacity of sixteen and eighteen wire is given, but no smaller than fourteen is to be...
Uten tilgangsbegrensning - Om denne boken

Electrical Catechism: An Introductory Treatise on Electricity and Its Uses

George Defrees Shepardson - 1901 - 426 sider
...more than the current indicated in the following table : TABI.B OF CARRYING CAPACITY OF COPPER WIRES The lower limit is specified for rubber-covered wires,...not taken into consideration in the above tables. The carrying capacity of sixteen and eighteen wire is given, but no smaller than fourteen is to be...
Uten tilgangsbegrensning - Om denne boken

Laws of the State of Wisconsin

Wisconsin - 1901 - 884 sider
...105,500 133, 100 107,800 211,000 CIRCULAR MILLS. 431. The lower limit is specified for rubber covered wires to prevent gradual deterioration of the high...the insulation. The question of drop is not taken in consideration in the above tables. Penalty for violations. SECTION 4. Any violation of the provisions...
Uten tilgangsbegrensning - Om denne boken

The Laws of Wisconsin

Wisconsin - 1901 - 900 sider
...105,500 133, 100 167,800 211,600 CIRCULAR MILLS. 431. The lower limit is specified for rubber covered wires to prevent gradual deterioration of the high...the insulation. The question of drop is not taken in consideration in the above tables. Penalty for violations. SECTION 4. Any violation of the provisions...
Uten tilgangsbegrensning - Om denne boken

Distributing system and lamps

Francis Bacon Crocker - 1901 - 514 sider
...Department having jurisdiction may require grounding if they deem it necessary. Ground Connections. The lower limit is specified for rubber-covered wires...the high insulations by the heat of the wires, but npt from fear of igniting the insulation. The question of drop is not taken into consideration in the...
Uten tilgangsbegrensning - Om denne boken

Electrical Catechism: An Introductory Treatise on Electricity and Its Uses

George Defrees Shepardson - 1901 - 434 sider
...rubber-covered wires, to prevent decentering of the wire and deterioration of the insulation by the heat but not from fear of igniting the insulation. The...not taken into consideration in the above tables. The carrying capacity of sixteen and eighteen wire is given, but no smaller than fourteen is to be...
Uten tilgangsbegrensning - Om denne boken

Agents' and Inspectators Pocket-book of Fire Protection

George Velten Steeb - 1902 - 230 sider
...vicinity, and they must be so arranged as to shunt the current through the building around any catch-box. The lower limit is specified for rubber-covered wires...not taken into consideration in the above tables. The carrying capacity of sixteen and eighteen-wire is given, but no smaller than fourteen is to be...
Uten tilgangsbegrensning - Om denne boken

Handbook on Engineering: The Practical Care and Management of Dynamos ...

Henry Charles Tulley - 1902 - 944 sider
...330 500 600,000 390 590 <;oo,ooo 450 680 i 700,000 500 760 800,000 550 840 900,000 (100 i»20 * - v The lower limit is specified for rubber-covered wires...not taken into consideration in the above tables. Insulation Resistance. — The wiring in any public building must test free from grounds ; ie, the...
Uten tilgangsbegrensning - Om denne boken